briteVAULT's 5 Data Center Locations
![Data Centers_2023.PNG](https://static.wixstatic.com/media/ba366b_0b1835f4a5474352abd3fadb1582bb6e~mv2.png/v1/fill/w_762,h_398,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/Data%20Centers_2023_PNG.png)
![](https://static.wixstatic.com/media/ba366b_fc15922ecb1e475a857cdbf98264af6c~mv2.png/v1/fill/w_152,h_17,al_c,q_85,enc_avif,quality_auto/ba366b_fc15922ecb1e475a857cdbf98264af6c~mv2.png)
briteVAULT US WEST1 (IRV) Data Center:
Los Angeles Metro
![Los Angeles](https://static.wixstatic.com/media/caf7d02d205a4d9d9d01d2f8928c96de.jpg/v1/fill/w_600,h_400,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/Los%20Angeles.jpg)
Facility Highlights:
~ SSAE 16 SOC 2 Type 2 Audited
~ 42,500 sq. ft.
~ 4 x 600KW Diesel Generators
~ Wet cell battery system to carry load transfer from utility to generator power
~ Double interlock pre-action dry pipe fire suppression
~ 10 Carrier fiber bandwidth blend
briteVAULT US West2 (IRV02) Data Center
Los Angeles Metro
![Image by Sven Piper](https://static.wixstatic.com/media/nsplsh_ee15fda3edc64585b657777d22521c42~mv2.jpg/v1/crop/x_1172,y_503,w_1425,h_1221/fill/w_600,h_514,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/Image%20by%20Sven%20Piper.jpg)
Facility Highlights:
~ SSAE 18/ ISAE 3402 SOC 1 Type 2
~ SSAE 18/ ISAE 3000 SOC 2 Type 2
~ ISO 27001
~ PCI DSS 3.2.1
~ NIST 800-53 PE
~ Uptime Institute Tier III Certified Facility
~ Uptime Institute Tier III Certified for Operational
Sustainability - Gold
~ 200,000 sq. ft.
~ N+1 UPS Systems plus N+1 Generator Systems
~ VESDA and pre-action dry pipe fire detection and suppression
~ 16 on-network Carriers
briteVAULT US West3 Data Center
Phoenix, Arizona
![Image by Ian Dziuk](https://static.wixstatic.com/media/nsplsh_9fcd76b3b7d241bb886073a1f025b202~mv2.jpg/v1/crop/x_1628,y_2363,w_2539,h_1697/fill/w_598,h_400,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/Image%20by%20Ian%20Dziuk.jpg)
Facility Highlights:
~ SSAE 16 SOC 2 Type 2 Audited
~ 575,000 sq. ft.
~ 8 x 2.25 MW and 16 x 2.5 MW Diesel Generators
~ Wet cell battery system to carry load transfer from utility to generator power
~ HFC-125 fire detection and suppression
~ 20 on-network Carriers
briteVAULT US Central1 Data Center
Dallas/Fort Worth, Texas
![Dallas, Texas cityscape with blue sky at sunset, Texas.jpg](https://static.wixstatic.com/media/ba366b_6a4ffc8937f04c64a54213d12f70413b~mv2.jpg/v1/fill/w_591,h_394,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/Dallas%2C%20Texas%20cityscape%20with%20blue%20sky%20at%20sunset%2C%20Texas.jpg)
Facility Highlights:
~ SSAE 16 SOC 2 Type 2 Audited
~ 373,700 sq. ft.
~ 40 MW utility and 38 MW generator power
~ Wet cell battery system to carry load transfer from utility to generator power
~ HFC-125 fire detection and suppression
~ 35 on-network Carriers
briteVAULT US East1 Data Center
Birmingham, Alabama
![Image by Zach Farmer](https://static.wixstatic.com/media/nsplsh_546b756e786f5339387130~mv2_d_7600_5036_s_4_2.jpg/v1/crop/x_266,y_600,w_3330,h_2217/fill/w_591,h_393,al_c,q_80,usm_0.66_1.00_0.01,enc_avif,quality_auto/Image%20by%20Zach%20Farmer.jpg)
Facility Highlights:
~ SSAE 16 SOC 2 Type 2 Audited
~ 31,000 sq. ft.
~ 5 MW utility with N+1 generator power
~ N+1 UPS
~ 150 mph wind-rated with 10" reinforcedconcrete walls
~ Enhanced security uilizing CUI (Controlled Unclassified Information) standards
~ 6 on-network Carriers